Cold Room - Exporter & Manufacturer, New Delhi, India
BRIGHT STAR COOLER
Home Page +
Company Profile +
Showroom +
Air-conditioning Equipment +  
Cold Room

Product Code : 05

[Select]
Product Specification

Cold Rooms:

Our cold rooms  are sturdy and robust in structure. They are made up of thick foam impact panels that provide insulation to the structure. Moreover, they have flexible or swing doors that facilitate easy putting in or taking out of material.

Features:

  • Employs latest technology.
  • Easy to use and to clean.
  • Standard aluminum hood and track.
  • Removable galvanized steel.
  • Negligible maintenance.

For the general purpose cold store, involving meats, vegetables and dairy products, it is common procedure to balance the unit cooler to the condensing unit at a 5.5 to 6.6oC (10 to 12oF) TD.
If this is done then from experience one can expect to maintain in a 1.7oC (35oF) room a 80 to 85 % relative humidity which is good range for general storage.
In a freezer room where the product is stored below 0oC (32oF) all moisture is in the form of ice or frost; the product is frozen solid and therefore a 5.5oC (10oC) TD is satisfactory for all products.

TECHNICAL DATA OF UNITS FOR SMALL AND MEDIUM COLD ROOMS FOR AN INSIDE TEMP RANGE OF (-4 Deg.C to 6 Deg.C) REFRIGERANT USED R-22, R-134a, R-404a
MODEL BSC -0.6 BSC-0.75 BSC-1.0 BSC-1.25 BSC-1.5 BSC-2.0 BSC-2.5 BSC-2.75
TONS OF REF. 0.6 0.75 1.0 1.25 1.5 2 2.5 2.75
COLD ROOM OF EXTERNAL SIZE IN METRES 2.5 x 2.5 x 2.4 3.5 X 2.5 X 2.4 3.5 X 3.5 X 3.0 4.0 X 4.0 X 3.0 5.0 X 4.0 X 3.0 6.0 X 4.5 X 3.0 6.0 X 5.5 X 3.0 7.0 X 6.5 X 3.0
AVERAGE POWER CONSUMPTION FOR R 22 0.75 KWH 1.05 KWH 1.20 KWH 1.45 KWH 1.85 KWH 2.35 KWH 2.80 KWH 3.25 KWH
AVERAGE POWER CONSUMPTION FOR R-134a 0.65 KWH 0.80 KWH 1.05 KWH 1.25 KWH 1.40 KWH 2.10 KWH 2.30 KWH 2.75 KWH
AVERAGE POWER CONSUMPTION FOR R 404A 0.75 KWH 1.05 KWH 1.30 KWH 1.55 KWH 1.95 KWH 2.50 KWH 2.90 KWH 3.35 KWH

Note: 1) The above units are rated at (+) 2 Deg. C Inside Room Temp.
2) We can also deisgn the unit as per our customers' requirement.

TECHNICAL DATA OF UNITS FOR SMALL AND MEDIUM COLD ROOMS FOR AN INSIDE TEMP RANGE OF (-5 Deg.C to -20 Deg.C) REFRIGERANT USED R-404a
MODEL BSC -0.5 BSC-0.75 BSC-1.0 BSC-1.25 BSC-1.5> BSC-1.65 BSC-1.8 BSC-2.0
TONS OF REF. 0.5 0.75 1.0 1.25 1.5 1.65 1.8 2.0
COLD ROOM OF EXTERNAL SIZE IN METRES 2.5 x 2.5 x 2.4 3.5 X 2.5 X 2.4 3.5 X 3.5 X 3.0 4.0 X 4.0 X 3.0 5.0 X 4.0 X 3.0 6.0 X 4.5 X 3.0 6.0 X 5.5 X 3.0 7.0 X 6.5 X 3.0
AVERAGE POWER CONSUMPTION FOR R-404a 1.45 KWH 2.45 KWH 2.85 KWH 3.40 KWH 4.50 KWH 5.00 KWH 5.50 KWH 6.10 KWH

Note: 1) The above units are rated at (-)20 Deg. C Inside Room Temp.
Other Products
Single Skin Horizontal Floor Mounted Air Handling Unit (Double Blower-Belt Driven)
Single Skin Horizontal Floor Mounted Air Handling Unit (Double Blower-Belt Driven)
Single  Skin Horizontal Floor Mounted Air Handling Unit (Single Twin Blower-Belt Driven )
Single Skin Horizontal Floor Mounted Air Handling Unit (Single Twin Blower-Belt Driven )
PUF Slabs
PUF Slabs
Fan Coil Unit
Fan Coil Unit
Strip Air Curtain
Strip Air Curtain
Double Skin Air Handling Unit (Horizontal Vertical Ceiling Suspended)
Double Skin Air Handling Unit (Horizontal Vertical Ceiling Suspended)
 
<< Back


  
The membership of this company with Tradeindia has expired. To view other companies related to this industry, kindly Click Here
Copyright © 2006 tradeindia.com. All Rights Reserved. Designed & Developed by